The fast growing electrification of mobility – particularly in public transport – requires high-performance mobile energy storage systems that enhance travel comfort. With E-Cooler Valeo has introduced a range of battery temperature management models with a maximum cooling capacity of 10 kW, offering an optimal solution for a wide range of applications. Depending on the requirement, the E-Cooler protects the battery from overheating during charging and discharging, cools it while driving at higher outside temperatures and heavy loads. An additional heating function even warms up the sensitive batteries if necessary to restore the optimum temperature range.
BCS : Standalone solution with active (optional passive) cooling circuit in the basic version.
Low life-cycle-costs
Safety
E-Cooler 100 BTM | E-Cooler 100T BTM | E-Cooler 50 BCS | E-Cooler 100 BCS | |
---|---|---|---|---|
Maximum cooling capacity (kW) at: outside temperature (°C) of coolant outlet (°C) of coolant flow (l/h) |
10 (8) 44 (approx. 50) 35 approx. 2,000 |
10 (12) 55 (44) 35 approx. 2,000 |
5 (approx. 6kW) 44 25 (35°C) 1,000 |
10 44 35 2,000 |
Maximum power consumption (compressor / fan) |
compressor 5A at 800V fan 21A at 28.5V |
compressor 5A at 800V fan 31A at 28.5V |
75A | 5A / 18A |
Maximum weight depending on design (kg) w/o coolant-carrying components |
85 | 115 | 60 | 55 |
Voltage (compressor / fan) V | 650 / 24 | 650 / 24 | 24 / 24 | 650 / 24 |
Dimensions L x W x H (mm) | appr. 1,200 x 511 x 350* | appr. 1,700 x 511 x 350* | 980 x 670 x 310 | 780 x 400 x 375 |
Coolant Filling capacity (kg) |
R134a approx. 1.5 |
R134a approx. 1.7 |
R134a | R134a |
active and passive cooling substation |
cooling only expansion tank, water pump, substation |
|||
SOP Q2/2024 | on demand | SOP Q3/2023 |
Contains flourinated greenhouse gases
Dimensions depend on the final power requirement and the outside temperature
Weight depend on design