REVO ®-E Global

All-electric unit for e- and hybrid buses

The REVO®-E Global is supplementing our range of all-electric rooftop air conditioning units and is specifically oriented to the demands of the global markets. A special emphasis was placed on lightweight construction, performance and simple installation. In addition to heat pump technology, customers also have the option of PTC heating and battery cooling.

Highlights

Low life-cycle costs

  • Low consumption of energy due to the low unit weight
  • Short dimensions allow space for battery system on the roof
  • Long duration due to brushless EC blowers
  • Nearly maintenance-free

Environmentally friendly

  • Safety against leakage due to the hermetically sealed refrigerant circuit
  • Noise emissions optimized

Comfort

  • Cooling capacity up to 33 kW
  • Heating with PTC heater or heat pump possible as an option
  • Tropical version: High cut off temperature of 55°C

Range of driving

  • Range of Driving: -20°C to +50°C
  • Maximized range due to reduced system weight and highly efficient heat pump down to -10°C (R407C)
  • Variable regulation of the PTC heater
  • Automatic de-icing function for energy saving heat pump operation at cold outside temperatures < 5°C
  • Flexibel and efficient power output due to infinitely variable compressor and fans
  • Electronic expansion valves (EEV) with Valeo control units for efficient operation with optimum high pressure control (optimal COP control)

Others

  • Integrated compressor, no installation of refrigerant lines necessary
  • Integrated plate heat exchanger for BTM
  • Designed R407C. Design for R134a on demand

Technical data

  Version 1
Cooling
Version 1
Trope Cooling
(up to 55°C)
Version 2
Cooling+ PTC heater
Version 3
Cooling + heat pump
Version 4
Cooling + heat pump + PTC heater + BTM
Integrated converter 24V DC / 380V DC 24V DC / 380V DC 24V DC / 380V DC 24V DC / 380V DC 24V DC / 380V DC
Max. cooling capacity (kW)
Refrigerant R134a (7)
Refrigerant R 407C

25
33

-
33

25
33

23
30

23
30
Max. heating capacity heat pump (kW) (6)
Refrigerant R134a (7)
Refrigerant R 407C
- - -
13
19

13
19
Max. heating capacity PTC (optional) (kW) - - 0-20 - 0-20
BTM capacity (kW)
during the ride
during the night charge

max 7
10

max 7
10

max 7
10

max 7
10

max 7
10
Current consumption (A) (26 V DC) nominal 70 (1) nominal 70 (1) nominal 70 (1) nominal 70 (1) nominal 70 (1)
Current consumption (A) (600V DC)
Refrigerant R134a (7)
Refrigerant R 407c

12²) / 7³)
18²) / 11³)

-
18²) / 11³)

12²) / 7³)
18²) / 11³)

12²) / 10 (4)
15²) / 14 (4)

12²) / 10 (4)
15²) / 14 (4)
Fresh air (optional) (5) 20% 20% 20% 20% 20%
Evaporator air flow m³/h 6,900 6,900 6,900 6,900 6,900
Unit weight (kg) 230 238 250 250 270
Cut-off temperature (°C) 50 55 50 50 55
Dimensions (L x W x H in mm) 3,100 x 1,900 x 295 3,550 x 1,900 x 295 3,100 x 1,900 x 295 3,100 x 1,900 x 295 3,100 x 1,900 x 295

  1. Nominal (condenser 80%, evaporator 70%)
  2. Max. cooling capacity (compressor speed 90 Hz)
  3. Regulated: temperature passenger compartment at set-point 27°C and ambient 35°C)
  4. Max. heat pump (compressor speed 90Hz)
  5. Referring of total free evaporator air flow;
  6. Heat Pump Application: 5ºC ≤ tAMBIENT ≤15ºC
  7. R134A on demand